Murphy LS200 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Switche sieciowe Murphy LS200. Murphy LS200 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
00-02-0671
2014-08-27
Section 15
LS200, LS200N and
LS200NDVOR Series Liquid Level
Switches
Installation and Operations Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - Switches

00-02-0671 2014-08-27 Section 15 LS200, LS200N and LS200NDVOR Series Liquid Level Switches Installation and Operations Manual

Strona 2

Section 15 00-02-0671 2014-08-27 - 6 - Installation and Adjustment for Pneumatic Models 1. All pneumatic models operate on the vent principle. T

Strona 3 - Table of Contents

Section 15 00-02-0671 2014-08-27 - 7 - Replacing and Installing the DVO Assembly NOTE: When replacing/installing the DVO assembly, tubing and fit

Strona 4

Section 15 00-02-0671 2014-08-27 - 8 - Figure 1 - DVO Figure 2 – Adjustable Orifice CAUTION: Ensure that the actuator arm is not bent during re

Strona 5 - Product Information

Section 15 00-02-0671 2014-08-27 - 9 - 14. Connect to the inlet, outlet and exhaust fittings according to installation drawings. Electrical Repl

Strona 6 - LS200NDVOR

Section 15 00-02-0671 2014-08-27 - 10 - LS200NDVO and LS200NDVOR 55050621: Regulator only 05706499: 20BPG-D-75 Pressure MURPHYGAGE®

Strona 7 - LS200NDVO

Section 15 00-02-0671 2014-08-27 - 11 - 15051098: External Float Chamber Operating pressure: 2000 psi (13.8 MPa) [138 bar] Operating temperatur

Strona 8

Section 15 00-02-0671 2014-08-27 - 12 - The Murphy Gas Compressor Scrubber Level System (SLS)

Strona 9

Section 15 00-02-0671 2014-08-27 - 13 - Specifications All Models Listed for Class I, Div. 1, Grp. C & D locations Canadian Registration Numbe

Strona 12

In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any t

Strona 14 - Accessories

Table of Contents Product Information ...

Strona 15

(THIS PAGE INTENTIONALLY LEFT BLANK)

Strona 16 - 2014-08-27 - 12

Section 15 00-02-0671 2014-08-27 - 1 - Product Information Features Listed for Class I, Div. 1, Grp. C & D locations Canadian Registration Num

Strona 17 - Specifications

Section 15 00-02-0671 2014-08-27 - 2 - LS200NDVOR LS200NDVOR is a float-activated, pneumatic-vent level device used to operate dump valves or simi

Strona 18

Section 15 00-02-0671 2014-08-27 - 3 - LS200NDVO Pneumatic level switch with Dump Valve Operator (DVO) without the pressure regulator for those ap

Strona 19

Section 15 00-02-0671 2014-08-27 - 4 - Pressure Vessel Installation: LS200 and LS200N Direct Installation into the Wall of the Pressure Vessel C

Strona 20

Section 15 00-02-0671 2014-08-27 - 5 - Installation with a Weld Collar 1. The weld collar, P/N 15050375, must be welded into the wall of the pres

Komentarze do niniejszej Instrukcji

Brak uwag