00-02-0841
2013-01-14
Section 20
EVS-2
Electronic Vibration Switch
Installation and Operations Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Electronic Vibration Switch

00-02-0841 2013-01-14 Section 20 EVS-2 Electronic Vibration Switch Installation and Operations Manual

Strona 2

Section 20 00-02-0841 2013-01-14 - 6 - Plug Options High-pressure (non-hollowed), forged steel pipe plug permanently welded to equipment or brack

Strona 3 - Table of Contents

Section 20 00-02-0841 2013-01-14 - 7 - Terminal Assignment The power supply +24 VDC voltage is connected via terminals 1 and 2. NOTE: Minimum vol

Strona 4

Section 20 00-02-0841 2013-01-14 - 8 - Figure 3 - EVS-2 Hook-up (showing only how to wire Channel 1 {K1})

Strona 5 - Product Information

Section 20 00-02-0841 2013-01-14 - 9 - Figure 3 - EVS-2 Hook-up (continued)

Strona 6 - Two-Channel LED Indicators

Section 20 00-02-0841 2013-01-14 - 10 - Settings Setting the Set-Point in Inches Per Second (IPS) Peak NOTE: The unit must be set per the appli

Strona 7 - Installation

Section 20 00-02-0841 2013-01-14 - 11 - Procedure Refer to the monitored machine recommended setting and mounting information and make appropri

Strona 8 - Mounting Options

Section 20 00-02-0841 2013-01-14 - 12 - Pot Settings The Vibration Setpoint potentiometers (pots) adjust the level detection based on the scale

Strona 9 - Mounting Examples

Section 20 00-02-0841 2013-01-14 - 13 - Setting of Alarms The alarm values may vary considerably, up or down, for different machines. The values

Strona 10 - Plug Options

Section 20 00-02-0841 2013-01-14 - 14 - Vibration Limits Based on Class of Equipment Based on ISO 10816-3 Figure 7 – Vibration Limits

Strona 11 - Terminal Assignment

Section 20 00-02-0841 2013-01-14 - 15 - Typical Vibration Alarm Settings of Various Installations THE VALUES LISTED BELOW ARE GUIDELINES ONLY –

Strona 12 - 2013-01-14 - 8

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any t

Strona 13 - 2013-01-14 - 9

Section 20 00-02-0841 2013-01-14 - 16 - Equipment Manufacturer Recommended Settings ARIEL: SKID, FRAMES, CYLINDERS (provided by Ariel) MICROLOG

Strona 14 - Settings

Section 20 00-02-0841 2013-01-14 - 17 - Specifications Performance Vibration Range (Adjust Jumper S1): 0.75, 1.50 or 3.00 IPS/peak Frequency Ra

Strona 15 - Procedure

THIS PAGE INTENTIONALLY LEFT BLANK

Strona 16

THIS PAGE INTENTIONALLY LEFT BLANK

Strona 18

Table of Contents Product Information ...

Strona 19

THIS PAGE INTENTIONALLY LEFT BLANK

Strona 20

Section 20 00-02-0841 2013-01-14 - 1 - Product Information Murphy EVS-2 Overview The Murphy Electronic Vibration Switch (EVS-2) protects against e

Strona 21 - Specifications

Section 20 00-02-0841 2013-01-14 - 2 - EVS-2 Characteristics and Orientation To prevent damage to the EVS-2 vibration switch, the following vibrat

Strona 22

Section 20 00-02-0841 2013-01-14 - 3 - Installation Mounting The Murphy EVS-2 must be mounted and set in accordance with the guidelines in this ma

Strona 23

Section 20 00-02-0841 2013-01-14 - 4 - Mounting Options The following diagrams illustrate example mounting options for the EVS-2 using a simple pi

Strona 24

Section 20 00-02-0841 2013-01-14 - 5 - Bracket Proposals Mounting Examples Legend: C=Compressor, E=Engine Compressor Cx (Compressor) = Cranksh